Untitled Document
 
Untitled Document

> Archives > Current Issues
JPE, Vol. 17, No. 3, May 2017
A Current Dynamic Analysis Based Open-Circuit Fault Diagnosis Method in Voltage-Source Inverter Fed Induction Motors
Lisi Tian, Feng Wu, Yi Shi, and Jin Zhao
Area Analysis, Modeling and Control
Abstract This paper proposed a real-time, low-cost, fast transistor open-circuit fault diagnosis method for voltage-source inverter fed induction motors. A transistor open-circuit changes the symmetry of the inverter topology, leading to different similarities among three phase load currents. In this paper, dynamic time warping is proposed to describe the similarities among load currents. The proposed diagnosis is independent of the system model and needs no extra sensors or electrical circuits. Both simulation and experimental results show the high efficiency of the proposed fault diagnosis method.
Keyword Dynamic time warping,Fault diagnosis,Open-circuit,Similarity measurement,Voltage-source inverter